The accuracy, precision and detection efficiency of boric acid content analysis methods in two commonly used nickel plating solutions were compared, namely separation determination and quick determination. The results show that the accuracy and precision of bot methods can meet the requirements of production testing, but the accuracy and precision of the former are better than that of the latter, and the detection efficiency of the latter is higher.